← All courses KANSAS STATE UNIVERSITY / ECE 685

ECE 685 / Interactive course platform

Power Systems Design

From generation planning to power flow. Learn, explore, and calculate, one lecture at a time.

LEARN → EXPLORE → COMPUTE

One lecture. One learning workspace.

Explore the full course in the original slide sequence. Completed lectures provide diagrams, interactive experiments, Python, and practice feedback.

Course overview

ECE 685 introduces the fundamentals of electric power systems engineering, with an emphasis on component modeling and the steady-state analysis and design of interconnected systems. It connects the economics of generation alternatives with three-phase circuits, transformer and transmission-line models, the per-unit method, and power flow.

Learning goals include calculating power in three-phase circuits, modeling transformers and transmission lines, analyzing systems in per unit, and running power flow simulations in PowerWorld. The web experiments and editable Python in each lecture help you check models, units, and power balances. The overview and learning goals follow the original syllabus; this platform uses the sixth-edition textbook.

Use “Ask AI” at the bottom right to ask about the course overview, prerequisites, learning sequence, or syllabus.

28 lectures available

Completed material follows the original lecture sequence: finalized slides, diagrams, experiments, Python, and practice are together on each lecture page. Upcoming content is marked to be released.

Explore the lectures

31 lectures

Course & power-system overview

2 lectures
L01Available

Course Orientation & Logistics

Meet the course team, explore the knowledge roadmap, and learn the tools and power-system design workflow.

L02Available

Power-System Evolution and Symbolic Representation

Trace the physical power system, construct a one-line diagram, and reconcile real and reactive power.

Generation mix planning

2 lectures
L03Available

Optimal Fuel Mix Analysis I

Demand, energy, capacity factor, planning reserve margin, and load-duration curves.

L04Available

Generation Mix Planning II

Build screening curves, find cost crossovers, form net load, and check a generation portfolio.

Single-phase AC circuits

3 lectures
L05Available

Single-Phase AC Circuits I

Map sinusoidal waveforms to RMS phasors; convert and add polar and rectangular representations.

L06Available

Single-Phase AC Circuits II

Calculate real, reactive, complex, and apparent power with consistent load and generator signs.

L07Available

Single-Phase AC Circuits III

Determine target reactive power, shunt compensation, and capacitance for power-factor correction.

Three-phase AC circuits

3 lectures
L08Available

Three-Phase AC Circuits I

Balanced sets, phase sequence, symmetrical components, and wye/delta voltage and current relations.

L09Available

Three-Phase AC Circuits II

Use per-phase equivalents to calculate three-phase power and reconcile source, line, and load.

L09bAvailable

Three-Phase AC Circuits

Worked examples on phase sequence, wye/delta conversion, branch currents, and feeder power balance.

Transformer modeling

3 lectures
L10Available

Transformer Modeling I

Derive ideal voltage and current ratios, power conservation, and impedance referral.

L11Available

Transformer Modeling II

Add winding resistance, leakage reactance, excitation, and checked equivalent-circuit approximations.

L12Available

Transformer Modeling III

Infer transformer parameters from open- and short-circuit tests; calculate regulation and efficiency.

Per-unit systems

3 lectures
L13Available

Per Unit System I

Choose coherent bases and normalize voltage, current, impedance, admittance, and power.

L14Available

Per Unit System II

Propagate bases through transformers and apply change of base across a multi-voltage network.

L15Available

Per Unit System III

Complete single-phase transformer and three-phase wye/delta normalization examples.

Three-phase transformers

2 lectures
L17Available

Three-Phase Transformers I

Build three-phase banks and distinguish winding, line, and bank relationships.

L18Available

Three-Phase Transformers II

Derive a balanced Y–Δ branch from actual terminal quantities and system bases; distinguish bank, autotransformer and tap ratios.

Transmission-line parameters

4 lectures
L22Available

Transmission-Line Parameters I

Separate material area, temperature and return geometry, then recover one-conductor and loop impedance.

L23Available

Transmission-Line Parameters II

Compute actual mutual distances and the geometric mean, then reproduce the transposed per-phase inductance.

L24Available

Transmission-Line Parameters III

Use physical radius to find capacitance, split a nominal π shunt and check phase current against three-phase reactive supply.

L25Available

Transmission-Line Parameters IV

Prepare one phase GMD and two bundle self-distances, then calculate parameter rates, route totals and a per-unit line branch.

Transmission-line models

3 lectures
L26to be released

Transmission-Line Models I

Construct the short-line model with declared terminal-current reference directions.

L27to be released

Transmission-Line Models II

Build the nominal-π circuit from series impedance and split shunt admittance.

L28to be released

Transmission-Line Models III

Derive distributed long-line equations, propagation constants, and terminal relationships.

Power-flow analysis

6 lectures
L32Available

Power Flow I

Connect devices, terminal directions, complex power and KCL before assigning generator controls.

L33Available

Power Flow II

Collect KCL coefficients into Y-bus, then calculate currents and powers at a trial voltage vector.

L34Available

Power Flow III

Specify slack/PV/PQ data, reproduce the solved three-bus case, and interpret a separate lossless line.

L35Available

Power Flow IV

Trace PQ and PV updates, distinguish intermediate estimates from completed-sweep mismatch, and test generator Q limits.

L36Available

Power Flow V

Connect tangent intercepts, coupled corrections and the selected power-flow Jacobian.

L37Available

Power Flow VI

Track rebuilt Jacobians, corrections and original residuals through the accepted voltage state.

Outline source:ECE685_Course_Package_v2/01_lectures

ECE 685 · Course overview

Course learning assistant

Ask about course material, request an explanation, or follow up.

Ask what the course covers, what background you need, or where to start.