L22 / Transmission-line parameters
Transmission-Line Parameters I
Separate material area, temperature and return geometry, then recover one-conductor and loop impedance.
01 / UNDERSTAND & PREDICT
Understand the model, then predict the result
- Correct resistance for temperature and supplied conductor factors.
- Separate internal and external flux linkage under stated assumptions.
- Convert per-length rates to one-conductor and two-wire loop values.
Metal area is not outer area
Use the conducting aluminum area in ρℓ/A. Voids, strands and a steel core mean πr² need not equal the aluminum area. The radius in the magnetic example belongs to a separate ideal solid, nonmagnetic surrogate.
Temperature and supplied factors
The path and AC factors are supplied empirical inputs, not a skin-effect solver. The default AC factor is specified at 60 Hz; if frequency changes in edited code, a matching factor must be supplied.
Internal flux linkage
For a nonmagnetic solid conductor with uniform current density, a shell links only the enclosed current fraction. Integrating gives 0.05 mH/km. This ideal term is not a catalog model for a stranded steel-core conductor.
External linkage and ideal GMR
D is the equal-return spacing with D≫r, not a boundary where the field vanishes. Combining internal and external linkage gives the ideal solid-conductor GMR r exp(−1/4). Later lectures use supplied conductor GMR directly.
Conductor versus loop
Multiply rates by route length once. An equal two-wire loop includes both conductors, so its R and X are twice the one-conductor values. This factor does not carry into the balanced three-phase formula in L23.
Baseline example: check each step
- Convert area: 500 mm²=500×10⁻⁶ m². R′dc,20=0.056528 Ω/km; the km conversion contributes a factor of 1000.
- kT=1+0.00403×55=1.22165. R′ac,75=0.056528×1.22165×1.020×1.030=0.0725517 Ω/km.
- Rcond=0.0725517×120.7008=8.75705 Ω. Area scaling affects this resistance without redefining the independent magnetic radius.
- L′int=0.05000 and L′ext=0.2 ln(6/0.014)=1.21209 mH/km; total L′cond=1.26209 mH/km.
- Lcond=0.152335 H and Xcond=2π60Lcond=57.4291 Ω. The equal two-wire loop is 17.5141+j114.8582 Ω.
Cross-check the original slides
02 / EXPLORE
Change one input and explain the response
Double AAl, then double D. Explain why resistance halves while inductance changes logarithmically. Compare one-conductor and loop answers.
Advanced parameters / test readings
Preparing the model.
Resistance versus temperature
Internal and external inductance versus spacing
Current intermediate values and numerical checks
Resistance factors are supplied at 60 Hz. The magnetic calculation assumes nonmagnetic solid conductors, uniform current density and equal opposite currents with D≫r. Aluminum area and magnetic radius are independent inputs; this is not a detailed stranded/steel-core or skin-effect model.
03 / EDIT & COMPUTE
Edit code to reproduce the model independently
Reproduce the baseline, then modify the parameter scan. The source contains reusable independent model functions; edit the current function and inspect numerical checks.
case is a snapshot of the controls when you press Run. Call solve(case) and assign the final solution to result to plot it.
The first run needs internet access to download Python. Computation stays in your browser; the solver uses only the standard library.
Ready to run.
Output appears here.
Last Python run and current control reference
Inspect and edit the model source (advanced)
Edit this module's function and run again. case.module selects the module; solve(case) returns values, plots, and checks. The parameter experiment keeps the original JavaScript reference for comparison.
04 / CHECK & EXPLAIN
Companion experiment practice and feedback
L22 worked example: 75 mi=120.7008 km; ρ20=2.8264×10⁻⁸ Ω·m; AAl=500 mm²; α20=0.00403/°C; T=75 °C; kpath=1.020; kac,60=1.030. The separate solid magnetic surrogate has r=14 mm, D=6 m, f=60 Hz.
Practice uses fixed baseline inputs independently of the controls. Each field displays its tolerance.
See the worked solution
- Convert area: 500 mm²=500×10⁻⁶ m². R′dc,20=0.056528 Ω/km; the km conversion contributes a factor of 1000.
- kT=1+0.00403×55=1.22165. R′ac,75=0.056528×1.22165×1.020×1.030=0.0725517 Ω/km.
- Rcond=0.0725517×120.7008=8.75705 Ω. Area scaling affects this resistance without redefining the independent magnetic radius.
- L′int=0.05000 and L′ext=0.2 ln(6/0.014)=1.21209 mH/km; total L′cond=1.26209 mH/km.
- Lcond=0.152335 H and Xcond=2π60Lcond=57.4291 Ω. The equal two-wire loop is 17.5141+j114.8582 Ω.
Finally, explain in your own words
- What are the inputs, references, and main assumptions?
- Double AAl, then double D. Explain why resistance halves while inductance changes logarithmically. Compare one-conductor and loop answers.
- Did your code edit change physical parameters, the method, or representation bases? Which check helps identify that?
Passing numerical and understanding checks records this lecture’s companion practice as “practice checks passed.”