← All courses KANSAS STATE UNIVERSITY / ECE 685

L22 / Transmission-line parameters

Transmission-Line Parameters I

Separate material area, temperature and return geometry, then recover one-conductor and loop impedance.

Available36 slides
Conductor resistance and flux linkage

01 / UNDERSTAND & PREDICT

Understand the model, then predict the result

Finalized lecture slides

Open / download original PDF ↗

Follow the original explanations, diagrams, derivations, and examples in slide order, then use the companion experiment below.

L22 original slide 1 of 36
L22 · 1 / 36
Slide text
Loading slide text.

Figures and page order follow the student PDF for this lecture.

A 75-mile line has 500 mm² of aluminum and a 14 mm outside radius. Why do resistance and inductance need different geometric information, and when should the answer be doubled?
  • Correct resistance for temperature and supplied conductor factors.
  • Separate internal and external flux linkage under stated assumptions.
  • Convert per-length rates to one-conductor and two-wire loop values.
Conductor resistance and flux linkage: baseline circuit or quantitative model illustration
Model illustration at baseline inputs. Change the parameters in the next section to explore the live diagram.

Metal area is not outer area

R'_{dc,20}=\rho_{20}/A_{Al}

Use the conducting aluminum area in ρℓ/A. Voids, strands and a steel core mean πr² need not equal the aluminum area. The radius in the magnetic example belongs to a separate ideal solid, nonmagnetic surrogate.

Temperature and supplied factors

R'_{ac,T}=R'_{dc,20}[1+\alpha_{20}(T-20)]k_{path}k_{ac}

The path and AC factors are supplied empirical inputs, not a skin-effect solver. The default AC factor is specified at 60 Hz; if frequency changes in edited code, a matching factor must be supplied.

Internal flux linkage

L'_{int}=\mu_0/(8\pi)=5\times10^{-8}\ \mathrm{H/m}

For a nonmagnetic solid conductor with uniform current density, a shell links only the enclosed current fraction. Integrating gives 0.05 mH/km. This ideal term is not a catalog model for a stranded steel-core conductor.

External linkage and ideal GMR

L'_{cond}=2\times10^{-7}\ln\frac{D}{r e^{-1/4}}\ \mathrm{H/m}

D is the equal-return spacing with D≫r, not a boundary where the field vanishes. Combining internal and external linkage gives the ideal solid-conductor GMR r exp(−1/4). Later lectures use supplied conductor GMR directly.

Conductor versus loop

Z_{loop}=2(R_{cond}+j\omega L_{cond})

Multiply rates by route length once. An equal two-wire loop includes both conductors, so its R and X are twice the one-conductor values. This factor does not carry into the balanced three-phase formula in L23.

Baseline example: check each step

  1. Convert area: 500 mm²=500×10⁻⁶ m². R′dc,20=0.056528 Ω/km; the km conversion contributes a factor of 1000.
  2. kT=1+0.00403×55=1.22165. R′ac,75=0.056528×1.22165×1.020×1.030=0.0725517 Ω/km.
  3. Rcond=0.0725517×120.7008=8.75705 Ω. Area scaling affects this resistance without redefining the independent magnetic radius.
  4. L′int=0.05000 and L′ext=0.2 ln(6/0.014)=1.21209 mH/km; total L′cond=1.26209 mH/km.
  5. Lcond=0.152335 H and Xcond=2π60Lcond=57.4291 Ω. The equal two-wire loop is 17.5141+j114.8582 Ω.
Original slide headings for this lecture36
  1. 1Transmission-Line Parameters I
  2. 2Lecture outline
  3. 3PART 1 · Line configuration and units
  4. 4Overhead-line construction
  5. 5Series-line physics
  6. 6Area and outer radius
  7. 7Conductor quantities
  8. 8Per-length parameters
  9. 9Compatible length units
  10. 10PART 2 · Resistance
  11. 11Resistance per unit length
  12. 12Temperature
  13. 13Resistance corrections
  14. 14Total route resistance
  15. 15PART 3 · Inductance and reactance
  16. 16Current path and magnetic field
  17. 17Flux linkage defines inductance
  18. 18From inductance to AC reactance
  19. 19Why both internal and external flux?
  20. 20Internal linkage: only part of the current
  21. 21External linkage: why a logarithm?
  22. 22GMR absorbs the internal contribution
  23. 23Reactance and route totals
  24. 24PART 4 · Exercises
  25. 25Exercise 1: given and find
  26. 26Exercise 1: solution
  27. 27Exercise 2: given
  28. 28Exercise 2: find
  29. 29Ex. 2(a): resistance rate
  30. 30Ex. 2(a): operating resistance
  31. 31Ex. 2(a): route resistance
  32. 32Ex. 2(b): magnetic components
  33. 33Ex. 2(b): magnetic rates
  34. 34Ex. 2(c): magnetic route totals
  35. 35Ex. 2(c): conductor and loop
  36. 36Summary
Cross-check the original slides

02 / EXPLORE

Change one input and explain the response

Double AAl, then double D. Explain why resistance halves while inductance changes logarithmically. Compare one-conductor and loop answers.

Advanced parameters / test readings

Preparing the model.

Corrected AC resistance rate—
One-conductor route resistance—
Ideal internal inductance—
External inductance—
One-conductor inductance rate—
One-conductor route reactance—
Two-wire loop resistance—
Two-wire loop reactance—

Resistance versus temperature

Internal and external inductance versus spacing

Current intermediate values and numerical checks

Resistance factors are supplied at 60 Hz. The magnetic calculation assumes nonmagnetic solid conductors, uniform current density and equal opposite currents with D≫r. Aluminum area and magnetic radius are independent inputs; this is not a detailed stranded/steel-core or skin-effect model.

03 / EDIT & COMPUTE

Edit code to reproduce the model independently

Reproduce the baseline, then modify the parameter scan. The source contains reusable independent model functions; edit the current function and inspect numerical checks.

case is a snapshot of the controls when you press Run. Call solve(case) and assign the final solution to result to plot it.

Download teaching models

The first run needs internet access to download Python. Computation stays in your browser; the solver uses only the standard library.

Ready to run.

Output appears here.
Inspect and edit the model source (advanced)

Edit this module's function and run again. case.module selects the module; solve(case) returns values, plots, and checks. The parameter experiment keeps the original JavaScript reference for comparison.

04 / CHECK & EXPLAIN

Companion experiment practice and feedback

Fixed practice inputs

L22 worked example: 75 mi=120.7008 km; ρ20=2.8264×10⁻⁸ Ω·m; AAl=500 mm²; α20=0.00403/°C; T=75 °C; kpath=1.020; kac,60=1.030. The separate solid magnetic surrogate has r=14 mm, D=6 m, f=60 Hz.

Practice uses fixed baseline inputs independently of the controls. Each field displays its tolerance.

±0.0001 Ω/km
±0.002 Ω
±0.002 Ω

Which area belongs in the resistance formula for a stranded conductor?

Finally, explain in your own words

  1. What are the inputs, references, and main assumptions?
  2. Double AAl, then double D. Explain why resistance halves while inductance changes logarithmically. Compare one-conductor and loop answers.
  3. Did your code edit change physical parameters, the method, or representation bases? Which check helps identify that?

Passing numerical and understanding checks records this lecture’s companion practice as “practice checks passed.”

ECE 685 · L22

Course learning assistant

Ask about course material, request an explanation, or follow up.

Choose a context, then ask “What does this mean?”