← All courses KANSAS STATE UNIVERSITY / ECE 685

L23 / Transmission-line parameters

Transmission-Line Parameters II

Compute actual mutual distances and the geometric mean, then reproduce the transposed per-phase inductance.

Available31 slides
Three-phase GMD, GMR and transposition

01 / UNDERSTAND & PREDICT

Understand the model, then predict the result

Finalized lecture slides

Open / download original PDF ↗

Follow the original explanations, diagrams, derivations, and examples in slide order, then use the companion experiment below.

L23 original slide 1 of 31
L23 · 1 / 31
Slide text
Loading slide text.

Figures and page order follow the student PDF for this lecture.

Three positions are at x=−4, 0 and +6 m. Which single spacing can represent their unequal magnetic coupling after complete transposition?
  • Derive all mutual distances from physical positions.
  • Explain geometric averaging through one full transposition cycle.
  • Use catalog GMR directly and retain the per-phase interpretation.
Three-phase GMD, GMR and transposition: baseline circuit or quantitative model illustration
Model illustration at baseline inputs. Change the parameters in the next section to explore the live diagram.

Positions determine the three distances

D_{ij}=\sqrt{(x_i-x_j)^2+(y_i-y_j)^2}

P1=(−a,0), P2=(0,0), P3=(b cosθ,b sinθ). At θ=0, the arrangement is horizontal and D31=a+b. With a=b and θ=120°, it is equilateral. The angle is measured from +x, not the included P1–P2–P3 angle.

Why a geometric mean?

\ln D_m=\tfrac13(\ln D_{12}+\ln D_{23}+\ln D_{31})

Magnetic terms depend on logarithms of distance. Equal-length transposition averages those logarithms. Every phase occupies every position for one third of the route; an arithmetic mean does not preserve the linkage.

GMR is supplied self-distance

L'_{\phi}=2\times10^{-7}\ln(D_m/D_s)\ \mathrm{H/m}

Use the conductor GMR Ds from its data. The 0.7788r expression applies only to the ideal solid nonmagnetic conductor of L22; do not multiply a catalog GMR by 0.7788 again.

Balanced return and route reactance

I_a+I_b+I_c=0,\quad X_{\phi}=2\pi f L'_{\phi}\ell

The other two phase currents sum to the negative of the selected phase current. This is already included in the balanced per-phase formula. Multiply by route length once and by ω to obtain one phase branch reactance.

Averaged model has a scope

D_m=(D_{12}D_{23}D_{31})^{1/3}

This scalar positive-sequence rate assumes complete equal-length transposition, identical conductors and balanced operation. Earth and shield wires are omitted. An untransposed line generally requires phase-domain coupling information.

Baseline example: check each step

  1. D12=4 m, D23=6 m, D31=10 m. Dm=(4×6×10)⅓=6.214465 m.
  2. GMR=0.01090 m. ln(Dm/Ds)=6.345872; L′φ=1.269174 mH/km.
  3. X′φ=2π60×1.269174×10⁻³=0.4784675 Ω/km. Lφ=0.153190 H and Xφ=57.7514 Ω.
  4. Using the arithmetic mean 6.6667 m gives about 58.3906 Ω, 1.107% too high. Substituting a 14 mm physical radius for GMR gives about 55.4736 Ω, 3.944% too low.
Original slide headings for this lecture31
  1. 1Transmission-Line Parameters II
  2. 2Lecture outline
  3. 3PART 1 · Three-phase configuration
  4. 4Three-phase conductor arrangements
  5. 5Tower positions and phase labels
  6. 6Three-phase current return
  7. 7Unequal spacing
  8. 8PART 2 · GMR and phase inductance
  9. 9Conductor data for inductance
  10. 10Magnetic self-distance
  11. 11Conductor GMR
  12. 12Three-phase flux linkage
  13. 13Equal spacing
  14. 14PART 3 · Transposition and reactance
  15. 15Conductor transposition
  16. 16Complete transposition
  17. 17Geometric mean distance
  18. 18Phase inductance rate
  19. 19Reactance rate and total
  20. 20PART 4 · Exercises
  21. 21Exercise 1: given and find
  22. 22Exercise 1: solution
  23. 23Exercise 2: given
  24. 24Exercise 2: find
  25. 25Ex. 2(a): position spacings
  26. 26Ex. 2(a): GMD
  27. 27Ex. 2(b): magnetic ratio
  28. 28Ex. 2(b): parameter rates
  29. 29Ex. 2(c): route totals
  30. 30Ex. 2(d): comparisons
  31. 31Summary
Cross-check the original slides

02 / EXPLORE

Change one input and explain the response

Set both position spacings to 6 m and the +x angle to 120°. Verify that all distances and GMD are 6 m. Then double only frequency and explain which quantities change.

Advanced parameters / test readings

Preparing the model.

Position distance D12—
Position distance D23—
Position distance D31—
Geometric mean distance—
Per-phase inductance rate—
Per-phase reactance rate—
Route phase reactance—
Error from using arithmetic mean—

Inductance versus uniform spacing scale

Route reactance versus frequency

Current intermediate values and numerical checks

One conductor per phase, identical supplied GMR, complete equal-length transposition and balanced currents; earth and shield wires omitted. The position diagram depicts the geometry that is averaged, not three permanently fixed phase identities.

03 / EDIT & COMPUTE

Edit code to reproduce the model independently

Reproduce the baseline, then modify the parameter scan. The source contains reusable independent model functions; edit the current function and inspect numerical checks.

case is a snapshot of the controls when you press Run. Call solve(case) and assign the final solution to result to plot it.

Download teaching models

The first run needs internet access to download Python. Computation stays in your browser; the solver uses only the standard library.

Ready to run.

Output appears here.
Inspect and edit the model source (advanced)

Edit this module's function and run again. case.module selects the module; solve(case) returns values, plots, and checks. The parameter experiment keeps the original JavaScript reference for comparison.

04 / CHECK & EXPLAIN

Companion experiment practice and feedback

Fixed practice inputs

L23 example: positions (−4,25), (0,25), (+6,25) m; GMR=10.90 mm; 75 mi=120.7008 km; f=60 Hz. The common height cancels in mutual distances because this model omits earth.

Practice uses fixed baseline inputs independently of the controls. Each field displays its tolerance.

±0.001 m
±0.001 mH/km
±0.002 Ω

Why is GMD geometric rather than arithmetic?

Finally, explain in your own words

  1. What are the inputs, references, and main assumptions?
  2. Set both position spacings to 6 m and the +x angle to 120°. Verify that all distances and GMD are 6 m. Then double only frequency and explain which quantities change.
  3. Did your code edit change physical parameters, the method, or representation bases? Which check helps identify that?

Passing numerical and understanding checks records this lecture’s companion practice as “practice checks passed.”

ECE 685 · L23

Course learning assistant

Ask about course material, request an explanation, or follow up.

Choose a context, then ask “What does this mean?”