L25 / Transmission-line parameters
Transmission-Line Parameters IV
Prepare one phase GMD and two bundle self-distances, then calculate parameter rates, route totals and a per-unit line branch.
01 / UNDERSTAND & PREDICT
Understand the model, then predict the result
- Derive the common phase GMD from equal transposition sections.
- Distinguish member GMR, outside radius and the two bundle self-distances.
- Build one circuit’s R/X/B record, then compare base changes and parallel circuits.
One mutual distance for inductance and capacitance
D12, D23 and D31 describe fixed phase-bundle positions. In three equal transposition sections, a phase pair experiences each spacing once. Average the logarithmic effects, rather than the distances. Magnetic linkage and electric potential have the same mutual-distance logarithm, so both use the same Dm. The phase-center approximation requires the bundle to be small relative to phase spacing.
Start with the self term of one member
A member’s magnetic self-distance is its supplied GMR Ds. The relation Ds=re^(−1/4) applies to a solid round nonmagnetic conductor with uniform current; use supplied GMR for stranded conductors. Electric potential is evaluated at the surface, so its self term is the physical radius r=Dout/2. Neither member input is yet the whole bundle’s self-distance.
The same bundle geometry, two self-distances
For a two-member phase, equal sharing averages ln(Dm/s) and ln(Dm/d), giving the equivalent self-distance √(sd). Use s=Ds for magnetic flux and s=r for electric potential. The same distance product extends to equilateral triples and square quadruples; d is the adjacent member-center spacing.
The square diagonal matters
A square member has two neighbors at d and one at √2d. The √2 factor inside the fourth root belongs in both the magnetic and electric bundle radius. The phase-center GMD approximation requires a bundle much smaller than phase spacing.
One phase contains the whole bundle
Symmetric identical members share phase current and charge equally. R′phase=R′sub/n. Mutual magnetic coupling means inductance cannot be divided by n as if the members were independent inductors.
One circuit’s physical parameters
Calculate per-phase L and C using phase-center GMD and the respective bundle self radii. Multiply each rate by route length once. Three phases are represented by one balanced phase branch, not an extra factor of three in R, X or B.
Series and shunt use reciprocal bases
Use line-to-line kV and total three-phase MVA for ZB in ohms. Divide series ohms by ZB; multiply shunt siemens by ZB. bpu is the total shunt, split into bpu/2 at each π end.
Bundle count is not circuit count
Two identical uncoupled circuits connected to the same buses give Zeq=Z/2 and Beq=2B. The individual circuit records remain unchanged. This approximation omits inter-circuit coupling and says nothing about thermal MVA limits.
Baseline example: check each step
- Use the revised slide data in SI: phase spacings 9.7536, 9.7536 and 19.5072 m; d=0.4572 m; member Ds=0.01792224 m; r=44.7548/2 mm=0.0223774 m. Member AC resistance rate is 0.0344488189 Ω/km.
- Prepare the geometry: Dm=(9.7536²×19.5072)^(1/3)≈12.2888 m; DsL=√(0.01792224×0.4572)≈0.0905210 m; DsC=√(0.0223774×0.4572)≈0.101148 m. Use the same Dm for L and C, but different self-distances.
- R′phase=0.01722441 Ω/km; L′phase=0.98217182 mH/km; X′phase=0.37027005 Ω/km. The 80-mile circuit has R=2.2176 Ω and X≈47.67135 Ω per phase.
- C′n=11.590456 nF/km; Ctotal≈1.492242 μF; Btotal≈0.56256215 mS. At 500 kV, QC≈140.640538 Mvar.
- ZB=500²/100=2500 Ω. rpu=0.00088704; xpu≈0.01906854; bpu≈1.40640538. Each π end gets bpu/2.
- For two identical uncoupled circuits on the same base, divide r and x by two and multiply total b by two. Changing only Sbase changes pu values while physical circuit ohms and siemens stay fixed.
Cross-check the original slides
02 / EXPLORE
Change one input and explain the response
Compare 1–4 members while keeping phase positions fixed: which self-distances change and why does Dm stay fixed? Then change a phase-position spacing and compare the L/C response. Finally select two physical circuits and change Sbase, distinguishing parallel equivalencing from a base change.
Advanced parameters / test readings
Preparing the model.
Reactance versus bundle count
Capacitance versus bundle count
Current intermediate values and numerical checks
Symmetric identical bundles with equal member sharing; complete transposition, balanced operation and phase-center mutual-distance approximation. Air dielectric, no earth/shield wires, corona or inter-circuit mutual coupling. Resistance is supplied AC data at 25 °C. Charging uses uniform voltage. Parameters do not determine a thermal MVA rating.
03 / EDIT & COMPUTE
Edit code to reproduce the model independently
Reproduce the baseline, then modify the parameter scan. The source contains reusable independent model functions; edit the current function and inspect numerical checks.
case is a snapshot of the controls when you press Run. Call solve(case) and assign the final solution to result to plot it.
The first run needs internet access to download Python. Computation stays in your browser; the solver uses only the standard library.
Ready to run.
Output appears here.
Last Python run and current control reference
Inspect and edit the model source (advanced)
Edit this module's function and run again. case.module selects the module; solve(case) returns values, plots, and checks. The parameter experiment keeps the original JavaScript reference for comparison.
04 / CHECK & EXPLAIN
Companion experiment practice and feedback
Revised L25 example: one 500 kV, 60 Hz circuit, 128.74752 km long; phase-bundle center spacings 9.7536, 9.7536 and 19.5072 m. Two members per phase with d=0.4572 m; member GMR Ds=0.01792224 m; outside diameter Dout=44.7548 mm. Supplied member AC resistance rate at 25 °C is 0.0344488189 Ω/km. Bases: 500 kV and 100 MVA.
Practice uses fixed baseline inputs independently of the controls. Each field displays its tolerance.
See the worked solution
- Use the revised slide data in SI: phase spacings 9.7536, 9.7536 and 19.5072 m; d=0.4572 m; member Ds=0.01792224 m; r=44.7548/2 mm=0.0223774 m. Member AC resistance rate is 0.0344488189 Ω/km.
- Prepare the geometry: Dm=(9.7536²×19.5072)^(1/3)≈12.2888 m; DsL=√(0.01792224×0.4572)≈0.0905210 m; DsC=√(0.0223774×0.4572)≈0.101148 m. Use the same Dm for L and C, but different self-distances.
- R′phase=0.01722441 Ω/km; L′phase=0.98217182 mH/km; X′phase=0.37027005 Ω/km. The 80-mile circuit has R=2.2176 Ω and X≈47.67135 Ω per phase.
- C′n=11.590456 nF/km; Ctotal≈1.492242 μF; Btotal≈0.56256215 mS. At 500 kV, QC≈140.640538 Mvar.
- ZB=500²/100=2500 Ω. rpu=0.00088704; xpu≈0.01906854; bpu≈1.40640538. Each π end gets bpu/2.
- For two identical uncoupled circuits on the same base, divide r and x by two and multiply total b by two. Changing only Sbase changes pu values while physical circuit ohms and siemens stay fixed.
Finally, explain in your own words
- What are the inputs, references, and main assumptions?
- Compare 1–4 members while keeping phase positions fixed: which self-distances change and why does Dm stay fixed? Then change a phase-position spacing and compare the L/C response. Finally select two physical circuits and change Sbase, distinguishing parallel equivalencing from a base change.
- Did your code edit change physical parameters, the method, or representation bases? Which check helps identify that?
Passing numerical and understanding checks records this lecture’s companion practice as “practice checks passed.”